Date: 9/18/1998, 4:38 pm
>
> If you cant get good ventilation in those sealed areas you will want to
> occasionally rinse the inside of these sealed up areas with a solution of
> disinfectant or mold and mildew killer. A weak solution of ordinary
> laundry bleach should work fine. A tablespoon or two of bleach in a quart
> of water should do. Pour in a cup or two of the mixture, slosh it around
> and drian it out.
Paul, Another excellent post, full of good ideas. One suggestion I might make, avoid the use of bleach to kill the mold/mildew. As was pointed out in another thread some while back, the chlorine (however weak) might want to oxidize the epoxy. You might want to try boric acid solution (weak) or antifreeze instead. But, I would recommend trying either of those on test panels first, just to make sure they don't attack the epoxy either.
Messages In This Thread
- Venting A Sealed Compartment
Jim Ward -- 9/15/1998, 4:16 pm- Everyone wants to vent
Paul Jacobson -- 9/18/1998, 4:19 am- Re: Everyone wants to vent
Rick VanBuren -- 9/18/1998, 4:38 pm- vent and w(h)ine
Paul Jacobson -- 9/19/1998, 9:26 pm
- Re: Everyone wants to vent
Mike Spence -- 9/18/1998, 3:14 pm - vent and w(h)ine
- Re: Venting - it's not a problem
Jay Babina -- 9/17/1998, 10:06 am- Re: Venting A Sealed Compartment
Pat Pavlik -- 9/16/1998, 10:56 pm- Re: Venting A Sealed Compartment
Mark Kanzler -- 9/16/1998, 4:02 pm- Re: Venting A Sealed Compartment
Jon K. -- 9/15/1998, 7:40 pm- Re: Venting A Sealed Compartment - MY SOLUTION
Jim Ward -- 9/15/1998, 8:59 pm- Re: Venting A Sealed Compartment - MY SOLUTION
Mark Kanzler -- 9/16/1998, 11:35 am- Re: Venting A Sealed Compartment - MY SOLUTION
Nolan Penney -- 9/16/1998, 8:45 am- Re: Venting A Sealed Compartment - MY SOLUTION
Scotty -- 9/16/1998, 11:28 am
- Comments on Your Solution
Jon K. -- 9/15/1998, 10:49 pm- Re: No Foam. Inspection Port In Bulkhead
Jim Ward -- 9/16/1998, 10:28 pm- Re: No Foam. Inspection Port In Bulkhead
Mark Kanzler -- 9/18/1998, 5:35 pm- Re: No Foam. Inspection Port In Bulkhead
Mark Kanzler -- 9/18/1998, 5:55 pm
- Re: No Foam. Inspection Port In Bulkhead
Nick Schade -- 9/17/1998, 5:01 pm- Re: PVC pipe fittings
Nolan Penney -- 9/17/1998, 8:01 am- Re: No Foam. Inspection Port In Bulkhead
Mike Spence -- 9/17/1998, 12:50 pm- Re: No Foam. Inspection Port In Bulkhead
Rick VanBuren -- 9/17/1998, 4:17 pm
- Re: No Foam. Inspection Port In Bulkhead
Pat Pavlik -- 9/16/1998, 11:56 pm- Flexible inspection plate
Mike Spence -- 9/17/1998, 12:17 pm
- Re: No Foam. Inspection Port In Bulkhead
- Re: No Foam. Inspection Port In Bulkhead
- Re: Venting A Sealed Compartment - MY SOLUTION
- Re: Venting A Sealed Compartment - MY SOLUTION
- Re: Venting A Sealed Compartment
L.C. -- 9/15/1998, 7:26 pm- Re: Venting A Sealed Compartment
Mark Kanzler -- 9/15/1998, 5:46 pm- Re: Venting A Sealed Compartment
Mark Carroll -- 9/15/1998, 4:46 pm- Re: Venting A Sealed Compartment
Jim Ward -- 9/15/1998, 5:23 pm
- Re: Venting A Sealed Compartment
Ross Leidy -- 9/15/1998, 4:34 pm- Re: Venting A Sealed Compartment
Martin Foil -- 9/16/1998, 3:10 pm- run a vent tube
Brian C. -- 9/15/1998, 5:30 pm- Re: run a vent tube
Jim Ward -- 9/15/1998, 6:19 pm- Re: run a vent tube
Rick C. -- 9/17/1998, 10:15 pm- Re: run a vent tube
Mark Kanzler -- 9/18/1998, 6:42 pm- Re: Gas mask valve
Mike Spence -- 9/18/1998, 3:01 am- Re: Gas mask valve
Mark Kanzler -- 9/18/1998, 6:55 pm- Re: Gas mask valve
Nolan Penney -- 9/18/1998, 7:01 am- Re: Gas mask valve
Mark Kanzler -- 9/18/1998, 7:03 pm- Re: Tandem valve....
Tor-Henrik Furmyr -- 9/19/1998, 6:42 pm- Re: Tandem valve....
Mark Kanzler -- 9/20/1998, 1:06 am- valveless `valve'
Paul Jacobson -- 9/19/1998, 8:44 pm - valveless `valve'
- Re: Tandem valve....
- Re: Gas mask valve
Rick C. -- 9/18/1998, 2:28 pm - Re: Tandem valve....
- Re: Gas mask valve
- Re: Gas mask valve
- Re: run a vent tube
- Re: run a vent tube
- Re: Venting A Sealed Compartment
Jim Ward -- 9/15/1998, 5:28 pm- Re: Idea #2
Nick Schade -- 9/16/1998, 5:57 pm- Re: Venting A Sealed Compartment
Nick Schade -- 9/16/1998, 5:44 pm- Re: Venting A Sealed Compartment
Ross Leidy -- 9/15/1998, 5:52 pm - Re: Venting A Sealed Compartment
- run a vent tube
- Re: Everyone wants to vent
- Everyone wants to vent